Measurement/ Instrumentation Lab


1. Displacement Measurement Tutor LVDT


• Range : 0 to 20 mm
• Display : 3-1/2 digit LED
• Resolution : 0.1 mm
• Excitation : 2 Volts RMS 5 KHz, Sinewave
• Power supply : 230V +/-10%, 50 Hz.
• Calibration Bench with 20mm micrometer.
• Test point also provided. Complete with operation manual.s

Experiments:

• To study waveform at different points.
• To plot Displacement vs. Digital Voltmeter reading.

2. Load Measurement Tutor Load Cell


• Range : 0 to 1 kg
• Display : 3-1/2 digit LED
• Resolution : 0.01 kg.
• Excitation : 5 Volts DC
• Power source : 230V +/-10%, 50 Hz.
• With 4 Nos. of 1/2 kg. weight.
• Test point also provided. Complete with Operating manual.

experiment:


• To plot Load Vs Digital Voltmeter reading
• To plot Load Vs Load Cell signal

3. Pressure Measurement Tutor Pressure Transducer


•Range : 0 to 10 kg/cm2
•Display : 3-1/2 digit LED
• Resolution : 0.1 kg/cm2
• Excitation : 5 Volts DC
• Power source : 230V +/-10%, 50 Hz.
• Hydraulic Pressure Generating Pump with pressure gauge of 10 kg/cm2
• Test Point also provided. Complete with Operating Manual.

Experiments:


•To plot Pressure Vs Digital Voltmeter reading
•To plot Pressure Vs Pressure cell signal

4. Strain Measurement Tutor Strain Cantilever Beam


•Range : 0 to 400 microstrain
•Display : 3-1/2 digit LED
• Resolution : 1 microstrain
• Excitation : 5 Volts, DC
• Power source : 230V +/-10%, 50 Hz.
• Strain Cantilever beam past full bridge strain gauges. With 4 Nos. Sliding weight of 250 gm.
• Test point also provided. Complete Operation manual./p>

Experiments:

• To plot Strain vs. Digital Voltmeter reading
• To plot Strain vs. Strain cell signal.

5. Torque Measurement Tutor Torque Transducer


•Range : 0 to 1 Kg-m.
• Resolution : 0.01 kg-m
• Display : 3-1/2 digit LED
• Excitation : 5 Volts DC
• Power source : 230V +/-10%, 50 Hz.
• With 4 Nos. Sliding Weight of 250 gm.
• Test Point also provided. Complete with operational manual.

Experiments:


• To plot Torque Vs. Digital Voltmeter reading
• To plot Torque vs. Torque Transducer signal.

6. Angular Measurement Tutor (Capacitive Transducer)


•Range : 0 to 360o
• Display : 3-1/2 digit LED
• Resolution : 1o
• Power source : 230V +/-10%, 50 Hz.
• Acrylic Jar with scale.
• Test Point also provided. Complete with Operating Manual.

Experiments:


• To plot Water Level Vs. Digital Voltmeter reading
• To plot Water Level Vs. Water Level Sensor signal

7. Temperature Measurement Tutor Using RTD Sensor


•Range : 100oC
• Display : 3-1/2 digit LED
• Resolution : 0.1oC
• Power source : 230V +/-10%, 50 Hz.
• Heating and cooling arrangement with Thermometer.
• Test point also provided. Complete with Operating Manual.

Experiments:


•To plot Temperature Vs. Digital Voltmeter reading
• To study of characteristics of RTD

8. Temperature Measurement Tutor Using Thermocouple


•Range : 100oC
• Display : 3-1/2 digit LED
• Resolution : 0.1oC
• Power source : 230V +/-10%, 50 Hz.
• Heating and cooling arrangement with Thermometer.
• Test point also provided. Complete with Operating Manual.

Experiments:

• To plot Temperature Vs. Digital Voltmeter reading
• To study of characteristics of Thermocouple.

9. Speed Measurements Tutor Using


• Range : Upto 2500 RPM
• Display : 3-1/2 digit LED
• Resolution : 1 RPM
• Power source : 230V +/-10%, 50 Hz.
• With small AC motor.
• Test Point also provided. Complete with operational manual.

Experiments:

• To plot Speed Vs. Digital Voltmeter reading
• To plot Speed Vs. Square wave of sensor

10. Dead Weight Pressure Gauge Tester


•Range : 0 to 50 kg/cm2
• Range : 0 to 100 kg/cm2
• With gauge connector of 1/2" BSP and complete with one set of weights in storage box, 1 instruction manual and tool box.